NOVAR 2100 R18 E - reactive power controller

NOVAR 2100 R18 E - reactive power controller NOVAR 2100 R18 E - reactive power controller NOVAR 2100 R18 E - reactive power controller +1

We will be happy to advise you:

NOVAR 2100 R18 E - reactive power controller

NOVAR 2100 R18 E reactive power controller 90 - 275 V AC, 18 stages (18 relays), 1f metering, digital input, power meter, Ethernet, USB service port. Controllers are fully automatic devices that monitor the condition of the LV/LV distribution network ...
NOVAR 2100 R18 E reactive power controller 90 - 275 V AC, 18 stages (18 relays), 1f metering, digital input, power meter, Ethernet, USB service port. Controllers are fully automatic devices that monitor the condition of the LV/LV distribution network and, based on fast and accurate calculations, connect or disconnect individual compensation or decompensation stages (capacitors, decompression inductors) to achieve the desired power factor.
show more
zobrazit méně
375,98 € excl. VAT
454,94 € incl. VAT

Order number: N2100R18E

The NOVAR 2100 is a basic model of the innovated NOVAR 2xxx PFC line. It builds on powerful modern platform shared among other PFC and PQ instruments and offers fast and precise single-phase measurement and advanced control.

Fast Ethernet supports embedded web server, Modbus RTU or TCP, SNTP, SNMP and other protocols. Optionally the local serial line (RS-485) can be used to remotely control and supervise the compensation cabinet. Manipulation with instrument data and configurations can be restricted only to authorized users and all Ethernet communication can be optionally secured by encryption.

NOVAR 2100 instrument shares its key features and parameters with NOVAR 2200, NOVAR 2400 and NOVAR 2600 controllers.

Key features

  • panel mount version, size 144x144 mm
  • common measuring voltage and power supply input
  • up to 18 outputs, Relay or Transistor (R09, R16, R18, R24)
  • measures and controls power factor in one line, for balanced loads
  • supports both low and high voltage applications (direct or VT connection)
  • combined mains compensation & de-compensation capability
  • evaluation of total harmonic distortion (THD) level by up to the 50-th harmonic
  • embedded four quadrant active and reactive energy meter class 0.5S and data logger
  • fully configurable alarm or cooling/heating control relay
  • USB for configuration as standard
  • RS-485 and Ethernet communication options
  • Active/reactive meter class 0.5S/2 with support for tariff and quadrants
Relay output 18
Supply voltage [V] 90 - 275 V AC, oddělené
Sensitivity 2 mA
Overvoltage category III - do 300V DC
Required power factor 0,8 ind. ÷ 0,8 kap.
Communication interface Ethernet, USB
Width [mm] 144
Depth [mm] 80
Height [mm] 144
Weight [g] 700
Mounting type Panel
Software NE
Protocols Modbus RTU
Relative humidity 5 až 100 %
Step value setting automatické nebo ruční
Connection mode setting automatické nebo ruční
Temperature measuring range/accuracy -30 ÷ 60 °C, ± 5 °C
Operating temperature -40... +60 °C
Degree of protection / IP rating zadní panel - IP20, čelní panel - IP40 (případně IP54)