FCR12T-3RS - power factor controller

We will be happy to advise you:

FCR12T-3RS - power factor controller

FCR 12T- 6RS Reactive power regulators FCR12T are designed for power factor control in LV 50Hz/60Hz networks with unbalanced loads. This series of regulators measures the current in all three phases and calculates the actual three-phase power. These ...
FCR 12T- 6RS Reactive power regulators FCR12T are designed for power factor control in LV 50Hz/60Hz networks with unbalanced loads. This series of regulators measures the current in all three phases and calculates the actual three-phase power. These are fast regulators, capable of regulating up to 17 times per second. The regulators have 6 and 12 outputs respectively for controlling contactor compensation or fast solid state stages switching at "ZERO". No delay is required for capacitor discharge when using CTU fast solid-state stages.
show more
zobrazit méně
512,57 € excl. VAT
620,21 € incl. VAT

In stock
Order number: FCR12T-3

FCR12T-3RS

The power factor controllers FCR06T and FCR12T are well proven controllers for LV and MV applications as well as for fast and hybrid thyristor power factor correction applications. The power factor controllers FCR06T and FCR12T offer advanced functionality, the automatic detection of measuring circuits and capacitor steps, three-phase current measurement, and also reliability and design for the hardest conditions.

In unbalanced systems it is necessary to measure current in each phase and calculate needed compensation power from real three-phase powers. FCR06T and FCR12T controllers are available with three current inputs.

  • 4 quadrant measurement and regulation
  • 3 phase current measurement via CT's
  • three regulation methods (APFR default)
  • ready for dynamic and hybrid PFC
  • universal CT input ../1A and ../5A
  • thyristor control speed up to 25 operations in 1 s
  • 6 or 12 regulated outputs
  • ready for de-compensation PFC

Function

Device digitizes measured phase voltage and current in one phase. Then, from those values, parameters like: power factor, effective values of voltage and current, apparent power and reactive power, are calculated. With consideration of requested cosφ it calculated need compensation power. According to its size, regulator switches on or off appropriate capacitor stages.

Within the scope of each power level, regulator uses method of circle switching. All the time connects this stage at appropriate power level which was switched off for longest time. Everything is made so that regulator will reach optimal compensation in one regulation cycle with minimum number of switched stages.

Alarmy

Power factor controllers FCR06T and FCR12T have several alarms which are adjustable by level, min time of event, action on regulated steps etc. Special alarm from temperature is able to control forced ventilation of PFC and protect capacitor steps against higher temperature.

Over temperature control

The controller offers the possibility of a temperature alarm working in two levels. The first level starts the ventilation of the cabinet. The second level disconnects all steps and gives an alarm notification on the display.

Cascade operation of two controllers

Two controllers in variant C can be connected together to expand the number of controlled steps or substitute for each other in a system with two main power supplies. Any one of controllers can behave as a master or slave.

Software

Thanks for software Power Monitor System is possible controllers with RS485 easily configured and also use for monitoring of PFC systems.

Supply voltage [V] 400 V AC 50 Hz +10%, -20%
Width [mm] 144
Depth [mm] 55
Height [mm] 144
Weight [g] 1500
Panel cutout 138 x 138 mm
Degree of protection / IP rating IP20