E13A1030.3 Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5

E13A1030.3 Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5 E13A1030.3 Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5 E13A1030.3 Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5

We will be happy to advise you:

E13A1030.3 Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5

High-precision plug-in current transformer by REDUR designed for current measurement up to 2000 A with a 5 A output. Accuracy class 0.5 ensures reliable readings even in demanding applications. Operating frequency 50 Hz. Ideal for switchgear ...
High-precision plug-in current transformer by REDUR designed for current measurement up to 2000 A with a 5 A output. Accuracy class 0.5 ensures reliable readings even in demanding applications. Operating frequency 50 Hz. Ideal for switchgear installations in industrial and energy sectors. Quick and easy installation thanks to plug-in design.
show more
zobrazit méně
72 € excl. VAT
87,12 € incl. VAT

Recycling fee 1 € included in the price

In stock
Order number: 0912888

13A1030.3 – Plug-in Current Transformer REDUR, 2000/5 A, Class 0.5

GENERAL TECHNICAL CHARACTERISTICS:

  • Maximum voltage for the device Um = 0.72 kV (other voltages on request)

  • Rated power-frequency withstand voltage: 3 kV / 1 min (other voltages on request)

  • Rated frequency: 50–60 Hz (other frequencies on request)

  • Rated continuous thermal current Icth = 1.2 x Ipr (1.0 x Ipr for higher primary currents)

  • Rated short-time thermal withstand current Ith = 60 x Ipr (max. 100 kA)

  • Rated dynamic current Idyn = 2.5 x Ith

  • Overcurrent limiting factor FS5 or FS10

  • Indoor operating condition

  • Ambient temperature (operation): -5 °C to +40 °C (other ranges on request)

  • Ambient temperature (storage/transport): -40 °C to +60 °C

  • Short-term primary conductor temperature: max. 170 °C for 1 s

  • Insulation class H (E / F for transformers with conformity assessment)

INFORMATION:

  • Weight approx. 440–680 g

  • Circular conductor diameter: 85 mm

  • Primary busbar options:

    • 2 x 100 x 10 mm

    • 3 x 80 x 10 mm

    • 4 x 50 x 10 mm

ACCESSORIES (INCLUDED):

  • 2 main rail terminals (type 16)

  • 4 threaded rods M5 x 55

  • 2 secondary terminal covers (yellow sliders)

  • 4 pressure pieces for rail-mounted primary fixation

  • Quick-clamping system for primary busbar (type 16-65)

  • Snap-on mounting for TS35 DIN rail (DIN EN 60715)

  • Insulating caps for primary mounting threaded rods

  • Plug-in feet

SECONDARY CONNECTION:

  • Nickel-plated +/- screws (2 Nm)

  • Integrated secondary terminal cover

  • Shatterproof polyamide housing

  • Flame retardant material

WARNING:
If the distance between the current transformer and adjacent current-carrying conductors is too small, the accuracy of measurement can be affected by external magnetic fields. For current transformers rated 2000 A and above, ensure a sufficient distance (at least 0.2 m), or use an optional version with external field protection (ffp5 / ffp10).

Sekundární výstup 5 A
Primární proud [A] 2000 A
Primary conductor - diameter [mm] Ø 85
Třída přesnosti 0,5
Width [mm] 129
Depth [mm] 30
Height [mm] 156
Hmotnost v [g] 500
Busbar – w x h [mm] 101 x 31