Compensating capacitors

VARTRON Power Factor Correction Capacitors Premium solution for perfect reactive-power compensation. Need assistance with PFC dimensioning? Our specialists will help you optimise your power factor and shorten your return on investment. Email: kbh@kbh.cz Tel: +420 777 730 002 1. Why choose VARTRON? Service life up to 150 000 h ...

VARTRON Power Factor Correction Capacitors

Premium solution for perfect reactive-power compensation.

Need assistance with PFC dimensioning? Our specialists will help you optimise your power factor and shorten your return on investment.

Email: kbh@kbh.cz Tel: +420 777 730 002

1. Why choose VARTRON?

  • Service life up to 150 000 h with proper rating and cooling – up to 50 % longer than conventional MKP capacitors.
  • Self-healing metallised polypropylene dielectric (MKP) – losses ≤ 0.2 W / kVAr and instant insulation recovery after local breakdown.
  • Integrated pressure-sensitive disconnector plus internal fuse – prevents destructive failure at end of life.
  • IP20 six-way terminal – safe and quick wiring with zero touch hazard.
  • Overload capability: continuous current up to 1.8 × IN, short-term over-voltage +30 % UN.
  • Next generation (2022): the improved VARTRON platform replaces the FORTIS II MKP series, delivering higher power density and enhanced protection.

2. Product Range & Key Parameters

Type Output [kVAr] Rated Voltage [V] Duty Class Ø × Height [mm]
VARTRON SD 0.5 – 25 400 / 440 / 525 Standard Duty Ø60 – Ø116 × 210 – 290
VARTRON HD 5 – 50 440 Heavy Duty Ø85 – Ø140 × 255 – 390

All variants: Δ-connection, 50 Hz, built-in discharge resistor, mounting stud.

3. Recommendations for 400 V Networks

Actual voltage in typical distribution systems can reach 420 – 430 V (±10 % tolerance).

  • Without detuning reactors: select 440 V capacitors to avert sustained over-voltage stress.
  • With detuning/reactor-protected PFC: always use 440 V capacitors to offset resonance-induced voltage rise and higher harmonics.

This simple practice extends capacitor life and reduces service interventions.

4. Standards & Certifications

VARTRON capacitors comply with IEC 60831-1/-2, EN 60831-1/-2, and UL 810, ensuring safe operation in industrial and commercial installations worldwide.

5. Typical Applications

  • Low-voltage PFC switchboards
  • Controlled capacitor banks with reactive-power controllers
  • Electric drives with high reactive-power peaks
  • Distribution boards exposed to harmonics (combined with detuning reactors)

6. Selecting the Right Capacitor

  1. Measure actual system voltage and THDi (total harmonic distortion).
  2. Determine required reactive power (kVAr) to achieve target power factor cos φ ≥ 0.95.
  3. Choose the rated voltage according to Section 3.
  4. Verify current rating and temperature class (-10 °C…+55 °C).
© 2025 KBH, a.s. | All rights reserved